Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
test_cases:all [2014/05/20 09:20]
grenier
test_cases:all [2014/07/29 17:56] (current)
grenier
Line 1: Line 1:
-An overview of the test cases considered so far is provided on a poster presented at EGU 2014 :+An overview of the test cases considered so far is provided on an actualized version of a poster formerly presented at EGU 2014, www.egu2014.eu (please click to enlarge):
  
-{{:test_cases:poster_benchmark_egu_2014.jpg?200|}}+{{ poster_benchmark_egu_2014_actualise.jpg?700 }}
  
-The poster is available as well for downloading as pdf file {{:test_cases:poster_benchmark_egu_2014.pdf|}}+The poster is available as well for downloading as pdf file {{:test_cases:poster_benchmark_egu_2014_actualise.pdf|}}
  
  
 ---- ----
 +
 +**Set of equations** 
 +
 +{{ equations.jpg?400 }}
 +
 +**Baseline for the validation & evaluation of codes** 
 +
 +The validation of the codes for the set of coupled TH equations will rely on three main types of action:
 +  - Comparison with analytical solutions: 1D purely heat transfer case by conduction with phase change.
 +  - Inter-comparison of codes for more complex test cases (1D & 2D, purely heat transfer to TH coupling). Data spread sheets are provided as well as performance measures allowing for simulation results comparison among participating codes. 
 +  - Confrontation with experimental results: some test cases were designed to be run in the laboratory in the framework of a collaboration with GEOPS laboratory (Univ. PARIS SUD, Orsay) equipped with a cold room facility. In the absence of analytical solutions, the experiment is a kind of ultimate solution. The difficulties associated with experimental setups adapted to coupled TH processes are large. Obtain an initial contrasted initial thermal field and control that the experiment box is impermeable and that the leakage of heat is controlled is a major challenge. 
 +
 +Even in the case of lab experiments where the maximum control on the experimental conditions and medium properties is researched and expected, some porous medium inhomogeneities, 3D effects, side leakages or difficulties in measuring some properties or parameters are probable. The “validation” of codes against such laboratory results will probably not be “the” ultimate solution one would wish. The confrontation between numerical and analogical simulation will thus require some level of calibration. This same difficulty is greatly amplified when considering a code validation relying on the confrontation with data issued from field monitoring. Such data corresponds to real world conditions that are more complex that lab experiments (e.g. multi-process, porous medium heterogeneities). The use of such field monitoring datasets is not contemplated for the present initial stand of the benchmark project. A longer perspective of the benchmark project is to propel the development of codes to deal with real world complex cases. More complex lab experiments and field monitoring will be included later on.  
 +
  
 **Detailed presentation of the test cases**  **Detailed presentation of the test cases** 
Line 13: Line 27:
   * T1, T2, T3: 1D pure heat transfer test cases, including the case with analytical solution   * T1, T2, T3: 1D pure heat transfer test cases, including the case with analytical solution
   * T->P: 1D heat transfer with pressure increase (no water flow)   * T->P: 1D heat transfer with pressure increase (no water flow)
-  * TH1, TH2: Coupled TH transfers+  * TH1, heat transfer with constant advection (analytical solution). TH2 and TH3: Coupled TH transfers
  
 An experiment in cold room associated with Case TH1 is ongoing.  An experiment in cold room associated with Case TH1 is ongoing. 
  
  
-[[test_cases:one|Case T1]]1D semi-infinite heat conduction case with phase change leading to analytical expressions                                  +[[test_cases:one|Case T1]] 1D semi-infinite heat conduction case with phase change leading to an analytical expression (Lunardini solution).                                  
  
-[[test_cases:two|Case T2]]     +[[test_cases:two|Case T2]] 1D vertical soil column with porous medium properties and geothermal flux, pure conduction with phase change    
  
-[[test_cases:three|Case T3]]                                 +[[test_cases:three|Case T3]] Similar case for geological time scale and the evolution of permafrost depths                                
  
-[[test_cases:four|Case T->P]] +[[test_cases:four|Case T->P]] Pressure increase associated with freezing front progression in volume controlled fully saturated porous medium
  
-[[test_cases:five|Case TH1]]+[[test_cases:seven|Case TH1]]  1D heat transfer with conduction, phase change and advection with constant velocity (analytical solution)
  
-[[test_cases:six|Case TH2]]+[[test_cases:five|Case TH2]] Initial frozen inclusion evolution (full coupling with inflowing water)
  
 +[[test_cases:six|Case TH3]] Closure / Opening of a talik due to challenging inflowing water and negative temperatures imposed on lateral sides